Lepu AIView VX has a minimalist and unique design, advanced technology, and innovative patented design to streamline caregivers' workflow and improve work efficiency. Various combinations can meet the needs of different clinical scenarios, such as a general ward, emergency room, recovery unit, etc.
Multi-parameter measurement: 3/5/12 leads ECG, Dual Temperature, SpO2 (blood oxygen saturation), NIBP (Non-invasive Blood Pressure), Respiration, PR (Pulse Rate) & ETCO2.
Advanced SpO2 anti-interference.
Detect and Analyze up to 28 types of arrhythmia events.
Low perfusion SpO2 algorithm with visual alarm.
Multi-Lead ECG algorithm with ST & QT analysis.
Unibody Accessory design with Patent.
Ergonomic & Concise Design.
EWS Early Warning Score:
* AIView VX patient monitor provides a point-of-care EWS (Early Warning Score) tool to assist clinicians or caregivers to recognize the early signs of clinical deterioration in order to initiate early intervention.
* Compliant with National Early Warning Score 2 (NEWS2), Modified Early Warning Score (MEWS), and Cardiac Arrest Risk Triage Score (CART).
* Initiative display of scoring value and radar-gram on the screen to remind clinicians anytime.
Excellent and Valuable IT Solutions.
Flexible Mounting and Carrying Solutions.
Product Name | Tablet Multiparameter Monitor |
Product Model | AIView VX |
Main Unit Size | Approx. 254mm(L)*190.5mm(W)*25.3mm(H) |
Display | Screen Type: 10.1-inch capacitive touchscreen Resolution 1280(RGB)×800 |
Operation Mode | Continuous operation |
Host Environment Specifications | Types |
Working Environment | |
Storage Environment | |
Temperature (℃) | 0℃~40℃ |
-20℃~60℃ | |
Battery supply | |
Rechargeable lithium battery: DC7.4V/5000mAh, non-removable | |
Working hours: Operating time ≥ 8 hours (in typical operating mode) | |
Relative humidity (non-condensing) | 15% to 95% |
10%~95% | |
Atmospheric pressure (kPa) | 57 kPa~107.4 kPa |
50.0 kPa~107.4 kPa | |
Power Supply Specifications | External power supply |
Input Voltage: AC 100V-240V; Input power:<50VA | |
Frequency: 50/60Hz | |
ECG Specifications | 3-lead electrodes: I, II, III 5-lead electrodes: I, II, III, aVR, aVL, aVF, V 6/10-lead electrodes: via Bluetooth for external M12 devices |
Heart Rate Measurement Range | Neonatal range: 15 to 350 bpm Pediatric range: 15 to 300 bpm Adult range: 15 to 300 bpm Measurement error: ± 1 bpm or ± 1%, whichever is greater |
Blood Oxygen Specification | Measurement Range: 0 ~ 100% Precision: 70%~100%:±2% Pulse rate range: 30~250 bpm Pulse rate accuracy: ±2% or ±2 bpm, whichever is greater |
Others | Contact us for more information |
Thank you for your attention on LEPU